OFF-GRID GENERATOR INTEGRATION SA

Solar first, generator only when you need it

Every off-grid system needs a plan for a run of cloudy winter days. For most farms and remote homes, that plan is a generator. The question is whether it runs only when it’s needed, or whether someone has to walk out and start it.

Generator integration connects the generator to your off-grid inverter, so the system starts it automatically when the battery gets low, charges the battery, and shuts it down again.

What it fixes

  • Flat batteries in a long cloudy spell
  • Starting the generator by hand
  • Generators running for hours more than they need to
  • Fuel and servicing costs
Off Grid Solar Power SA Yorke Solar SA
Chris Collins Off Grid

ALREADY RUNNING A GENERATOR?

From generator power to solar with a backup

If a generator is your main power source now, adding solar and a battery turns it into the backup. At a Balaklava grain shed, we replaced the 30 kVA generator with an off-grid solar and battery system.

Where a generator still makes sense as backup, we size the system so it runs as little as possible.

WHAT'S INVOLVED

Sizing, wiring and auto-start

  1. Check. We look at the generator, its size and whether it can auto-start, and the off-grid inverter.
  2. Design. We set when the generator starts and stops, based on battery level and load.
  3. Install. Changeover wiring, start cabling and protection, installed by our electricians.
  4. Test. We run it through a full start, charge and stop cycle with you.
Booleroo Off grid 3
Off Grid Trailer

WHY YORKE SOLAR

Off-grid specialists in regional South Australia

Family-owned and South Australian since 2018, based in Maitland and working across Adelaide and regional South Australia. Our own licensed electricians do the work; we don’t subcontract. Rated 5 out of 5 from more than 100 reviews.

We design and install off-grid solar systems for farms, sheds and remote homes, including on Kangaroo Island. A yearly health check keeps the battery, inverter and generator ready for winter.

COMMON QUESTIONS

Generator integration questions

Often, yes, if it has or can be fitted with an auto-start. We check the generator and inverter before quoting.

Yes, once integrated. The inverter starts it when the battery drops to a set level and stops it when the battery is charged.

Most do, as backup for long cloudy spells. A well-sized system keeps generator hours low.

In many cases solar and a battery can take over most of the load, with the generator kept only as backup.

Call 08 7111 0780, Monday to Friday, 8am to 5.30pm, or request a quote online.